PCB Annular Rings: Pad Size, Drill Tolerance and DFM Checks
MOZPCB Editorial Team (PCB manufacturing guides) · Updated 2026/11/24
A PCB annular ring is the copper surrounding a hole in a land or pad. On a plated through-hole or via, the relationship between the hole and surrounding copper is part of the connection between the hole wall and the conductor on that layer.
The common calculation, ring width = (pad diameter − hole diameter) / 2, describes concentric circular geometry. It does not account for hole position error, changes in copper dimensions or the distinction between drilling and finished-hole measurements. Use it to understand the layout, then confirm manufacturing and acceptance requirements separately.
Calculate the nominal radial ring on a circular pad
Let D be the copper-pad diameter and d the hole diameter, expressed in the same units and on the same dimensional basis. For a centered circular hole, a = (D − d) / 2. Dividing by two converts the diametral difference into the radial copper width on each side.
As a teaching example, D = 0.60 mm and d = 0.30 mm give a = 0.15 mm. These chosen values illustrate the equation; they are not a MOZPCB minimum or a recommended via size. Slots, non-circular pads and irregular copper edges need a geometry-specific minimum-distance check.
| Input or result | Value | Meaning |
|---|---|---|
| Copper-pad diameter D | 0.60 mm | Nominal circular pad in this example |
| Hole diameter d | 0.30 mm | Hole on a consistent, declared dimensional basis |
| Centered radial ring a | (0.60 − 0.30) / 2 = 0.15 mm | Nominal geometry before position offset |
| Illustrative center offset e | 0.05 mm | Chosen lateral offset, not a process tolerance |
| Narrowest ring in this geometry | 0.15 − 0.05 = 0.10 mm | Assumes unchanged, perfect circular boundaries |
What changes when the hole is off center?
For the same ideal circles with a lateral center offset e, the narrowest remaining radial distance is a − e. The opposite side becomes wider; averaging the two sides would hide the local narrow region. If the offset reaches the nominal ring width, the idealized hole boundary touches the pad edge.
Real boards also have dimensional and registration variation. Manufacturing review must consider the actual process and layer stack instead of treating the simple offset equation as a full tolerance model. Breakout and acceptance decisions depend on the applicable construction, criteria and agreed inspection method.
Do not fix an annular-ring concern by reducing a component hole without checking lead fit, finished-hole tolerance and soldering requirements. Increasing the pad can also reduce clearance to neighboring copper. Resolve the combined constraints before changing the footprint.
CAD hole, production drill and finished hole are different references
A fabrication drawing may specify the required finished hole, while the manufacturing process uses a production tool chosen to achieve it after the relevant operations. Plating changes the hole wall. Do not assume that a CAD hole value and a production drill diameter can be exchanged without checking the supplier’s convention.
State the finished-hole size and tolerance where fit matters, identify plated versus non-plated features, and ask the fabricator how the supplied data is interpreted. Record any proposed tool or pad change against the affected hole group and layers.
For a tolerance calculation, all terms must refer to compatible geometry. A ring computed from one hole basis cannot be compared directly with a minimum defined using another basis. Ask for clarification of the dimension and measurement stage before approving a DFM waiver.
Review each relevant layer and feature type
Inspect the land on each layer where the hole and copper need a defined relationship. An outer-layer pad does not establish the internal-layer geometry. Likewise, a clearance opening around a non-connected hole is not an annular ring that carries a connection.
Through vias, component holes, blind/buried vias and laser microvias have different construction requirements. The HDI design guide covers via architecture, while the via-in-pad guide addresses fill, cap and assembly requirements. Do not infer those requirements from the ring-width equation.
A teardrop can add copper near a trace-to-pad junction, but it does not automatically establish adequate ring around the entire hole. Check the full land, the connection and nearby clearances rather than treating one feature as a universal remedy.
Use CAD checks with agreed manufacturing rules
Set the annular-width and hole-size rules for the intended construction, then run design-rule checks. KiCad’s PCB Editor, for example, checks annular width and hole size separately; its minimum annular-width setting is a design constraint, not certification of a finished board.
Review the exported copper and drill data as well as the CAD result. Confirm that pad stacks, hole groups and plated/non-plated intent match the drawings. Use the Gerber preparation checklist to keep the layer map, drill data and release revision together.
Passing a nominal geometry check does not validate the supplier’s process margin. Request a review where dense routing, hole fit or a special via architecture leaves little room for manufacturing variation.
Turn a DFM question into an explicit drawing decision
Ask the fabricator to identify the affected feature, layer, current dimensions, proposed change and manufacturing reason. A note saying only “annular ring too small” is not enough to determine whether to enlarge a land, change routing or revise a hole requirement.
When an acceptance standard applies, identify the agreed document/revision, product class and relevant requirements with the supplier. This guide does not reproduce or replace a standard’s acceptance criteria.
| Question | Record in the approved package |
|---|---|
| Which features are affected? | Hole group or reference, span, layer and plated/non-plated intent |
| Which hole dimension is specified? | CAD convention, required finished hole and tolerance; manufacturing interpretation |
| What is the copper requirement? | Land geometry and layer-specific design/acceptance criteria |
| What else changes with a larger pad or different hole? | Lead fit, routing clearance, thermal connection and assembly implications |
| Who approves the change? | Named project approval role, revised files and superseded revision |
| How will acceptance be checked? | Applicable criteria, measurement/inspection scope and required records |
Request fabrication review with the hole requirements attached
Send the copper and drill files, layer map, hole table, finished-hole tolerances and any special via notes with your PCB fabrication RFQ. If a DFM question is already open, include the annotated feature and the constraint that prevents a simple pad or hole change.
The manufacturing capabilities provide an initial service overview. Final design rules must match the material, copper, layer count and hole construction for the actual order. Approve revised manufacturing data before tooling.
Frequently asked questions
How do I calculate annular ring width?
Is the minimum annular ring always the same for every PCB?
Can I make the hole smaller to increase the annular ring?
Does passing a CAD annular-ring check prove manufacturability?
Is solder-mask opening part of the annular-ring equation?
Related articles
- PCB Design Guide2026/04/15 · 5 min
What to Expect from a DFM Review on Your PCB Stackup
What a real PCB DFM review covers—annular rings, mask slivers, copper balance, finish trade-offs, HDI and flex risks, and test access—and how to answer questions without slowing your quote.
Read article - PCB Design2026/11/02 · 7 min
Via-in-Pad PCB: Fill, Cap and BGA Manufacturing Requirements
Via-in-pad can save routing space, but a pad location alone does not define the fill, cap, planarity or reliability requirements.
Read article - PCB Design Guide2026/05/12 · 5 min
HDI PCB Design Guide: Microvias, Stackups, and Cost Drivers
How microvia structures, sequential lamination, and via-in-pad decisions drive HDI cost and reliability—and how to choose the simplest stackup that routes your design.
Read article - PCB Manufacturing2026/04/01 · 6 min
Preparing Gerber Files for Smooth PCB Manufacturing
A practical Gerber and fabrication-data checklist: layer naming, drill parity, apertures, stackup notes, impedance tables, and panelization decisions that cut RFQ back-and-forth before tooling.
Read article